Run 100832 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v25
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-30T11:16:11+00:00
App 53
Duration 360.278 s
Run quality COMPLETE

Primary result

Signed field change: +365.2 nT (+2.022%)

Measure Value N / window
Reference field 18.061814 µT 1498 / 0–30 s
Outcome field 18.427012 µT 3000 / 240–300 s
Absolute change 365.2 nT same windows
Angular change 0.379° same windows

Continuous ambient comparison

Compared with 2 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -188.3 nT.

Summary: CONTROL; +365.2 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 49.9932 Hz effective over N=18006 samples, 1 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.00189745 µT/s (0.683366 µT over 0.0–360.1 s, N=18006)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal review see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
350–360 s 10 s 646.5 nT 23.19 500
348–358 s 10 s 634.4 nT 22.75 500
349–359 s 10 s 631.8 nT 22.66 500
346–356 s 10 s 631.3 nT 22.64 500
340–360 s 20 s 628.2 nT 22.53 1000
347–357 s 10 s 627.2 nT 22.49 500
345–355 s 10 s 621.6 nT 22.30 500
338–358 s 20 s 615.2 nT 22.07 1000
344–354 s 10 s 614.7 nT 22.05 500
330–360 s 30 s 613.6 nT 22.01 1500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.