Run 100406 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v16
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-22T01:00:53+00:00
App 38
Duration 300.913 s
Run quality COMPLETE

Primary result

Signed field change: +476.7 nT (+1.154%)

Measure Value N / window
Reference field 41.296384 µT 1501 / 0–30 s
Outcome field 41.773052 µT 2999 / 240–300 s
Absolute change 476.7 nT same windows
Angular change 0.533° same windows

Continuous ambient comparison

Compared with 9 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -1615.1 nT.

Summary: CONTROL; +476.7 nT; complete

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15005 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.00196427 µT/s (0.589439 µT over 0.0–300.1 s, N=15005)
Motion pass Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
287–297 s 10 s 619.2 nT 9.38 500
290–300 s 10 s 618.5 nT 9.36 499
286–296 s 10 s 616.5 nT 9.33 500
277–297 s 20 s 616.1 nT 9.33 1000
278–288 s 10 s 615.2 nT 9.31 500
276–296 s 20 s 614.4 nT 9.30 1000
289–299 s 10 s 614.0 nT 9.30 501
278–298 s 20 s 613.9 nT 9.30 1000
277–287 s 10 s 613.0 nT 9.28 500
285–295 s 10 s 612.9 nT 9.28 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.