Run 100395 — CONTROL

Practitioner unknown
Condition CONTROL
Analyzer maglab-analyzer v16
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-21T21:24:35+00:00
App 38
Duration 300.443 s
Run quality COMPLETE WITH DATA-QUALITY WARNING

Primary result

Signed field change: +186.8 nT (+0.339%)

Measure Value N / window
Reference field 55.145216 µT 1501 / 0–30 s
Outcome field 55.332048 µT 3000 / 240–300 s
Absolute change 186.8 nT same windows
Angular change 0.911° same windows

Continuous ambient comparison

Compared with 82 ordinary 300-second phone windows from the same UTC day, the ambient mean change was -1033.5 nT.

Summary: CONTROL; +186.8 nT; complete with data-quality warning

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15003 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts 0.0004008 µT/s (0.120263 µT over 0.0–300.0 s, N=15003)
Motion review Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
231–241 s 10 s 371.0 nT 4.72 500
230–240 s 10 s 367.4 nT 4.67 500
229–239 s 10 s 367.3 nT 4.67 500
256–266 s 10 s 364.0 nT 4.63 500
255–265 s 10 s 361.7 nT 4.60 500
232–242 s 10 s 360.9 nT 4.59 500
221–241 s 20 s 357.8 nT 4.55 1000
254–264 s 10 s 357.1 nT 4.54 500
220–240 s 20 s 355.5 nT 4.52 1000
253–263 s 10 s 355.3 nT 4.52 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.