Run 100303 — CONTROL

Practitioner Alex
Condition CONTROL
Analyzer maglab-analyzer v12
Report schema maglab-standard-report-v3
Analysis model maglab-analysis-v1
Generated UTC 2026-08-19T03:20:36+00:00
App 34
Duration 300.431 s
Run quality COMPLETE WITH DATA-QUALITY WARNING

Primary result

Signed field change: -136.4 nT (-0.120%)

Measure Value N / window
Reference field 113.249218 µT 1501 / 0–30 s
Outcome field 113.112836 µT 3000 / 240–300 s
Absolute change 136.4 nT same windows
Angular change 0.379° same windows

Continuous ambient comparison

Compared with 17 ordinary 300-second phone windows from the same UTC day, the ambient mean change was +4133.8 nT.

Summary: CONTROL; -136.4 nT; complete with data-quality warning

Sensor context

Check Status Detail
Readiness pass see metrics.json
Sampling measured calibrated magnetometer 50 Hz effective over N=15001 samples, 0 gaps
Warmup reported_unrecorded Phone-first warm-up occurred before Room recording; CSV t=0 is the first measurement sample.
Baseline Drift measured calibrated |B| drifts -0.0003816 µT/s (-0.11447 µT over 0.0–300.0 s, N=15001)
Motion review Gyro quiet/active split and motion-gate trips are both reported; they use distinct established thresholds.
Thermal pass see metrics.json
Ambient available Ambient context includes non-overlapping 300-second windows using the same 0–30 s versus 240–300 s outcome.
Rolling Anomaly measured Scores use feedback_meter level/drift_sigma. Both signs are treated symmetrically; ranked windows are descriptive.

Exploratory appendix — rolling windows

Start–end Length Signed change Score N
290–300 s 10 s -209.8 nT 3.61 500
289–299 s 10 s -206.6 nT 3.56 500
267–277 s 10 s -185.8 nT 3.20 500
266–276 s 10 s -183.4 nT 3.16 500
288–298 s 10 s -182.1 nT 3.14 500
265–275 s 10 s -178.6 nT 3.08 500
264–274 s 10 s -177.4 nT 3.06 500
262–272 s 10 s -172.5 nT 2.97 500
271–281 s 10 s -171.9 nT 2.96 500
263–273 s 10 s -171.2 nT 2.95 500

Files

Interpretation boundary

The primary result above is the fixed maglab-final-v1 comparison. Rolling windows describe how the run developed. Artifact masks annotate derived analysis only; no raw sample was changed or removed.